Mds 9132t 32g 1 Ru Fc Switch 8 Active Ports Exhaust Spare
ITCurry #: 0918W633 | Article #: DS-C9132T-MEK9-
SchermGeheugenGewichtProcessorHard DiskSSDSchermResolutieConnectiviteitGeheugenDesktopOSSchermTypeSnelheid ZwartSnelheid KleurenModelSnelheidVorm factorInterne / ExterneAantal poortenUplink / mediaMontage
- Alles bekijken
Bundles
Verwante producten
Product Informatie
The next-generation Cisco® MDS 9132T 32-Gbps 32-Port Fibre Channel Switch (Figure 1) provides high-speed Fibre Channel connectivity from the server rack to the SAN core. It empowers small, midsize, and large enterprises that are rapidly deploying cloud-scale applications using extremely dense virtualized servers, providing the dual benefits of greater bandwidth and consolidation. Small-scale SAN architectures can be built from the foundation using this low-cost, low-power, non-blocking, line-rate, and low-latency, bi-directional airflow capable, fixed standalone SAN switch connecting both storage and host ports. Medium-size to large-scale SAN architectures built with SAN core directors can expand 32-Gbps connectivity to the server rack using these switches either in switch mode or Network Port Virtualization (NPV) mode. Additionally, investing in this switch for the lower-speed (4- or 8- or 16-Gbps) server rack gives you the option to upgrade to 32-Gbps server connectivity in the future using the 32-Gbps Host Bus Adapter (HBA) that are available today. The Cisco® MDS 9132T 32-Gbps 32-Port Fibre Channel switch also provides unmatched flexibility through a unique port expansion module (Figure 2) that provides a robust cost-effective, field swappable, port upgrade option. This switch also offers state-of-the-art SAN analytics and telemetry capabilities that have been built into this next-generation hardware platform. This new state-of-the-art technology couples the next-generation port ASIC with a fully dedicated Network Processing Unit designed to complete analytics calculations in real time. The telemetry data extracted from the inspection of the frame headers are calculated on board (within the switch) and, using an industry-leading open format, can be streamed to any analytics-visualization platform. This switch also includes a dedicated 10/100/1000BASE-T telemetry port to maximize data delivery to any telemetry receiver including Cisco Data Center Network Manager.
Beheerfuncties | |
Switch type | Managed |
Web-gebaseerd management | Ja |
ARP-inspectie | Ja |
Locatie-instellingen (CLI) configureren | Ja |
System event log | Ja |
Poorten & interfaces | |
Aantal basis-switching RJ-45 Ethernet-poorten | 2 |
Type basis-switching RJ-45 Ethernet-poorten | Gigabit Ethernet (10/100/1000) |
Aantal Gigabit Ethernet (koper)-poorten | 2 |
Fibre channel-poorten | 8 |
Vezel-optische connector | SFP+ |
Console port | RS-232 |
Aantal USB 2.0-poorten | 1 |
Netwerk | |
10G support | Ja |
Koperen ethernetbekabelingstechnologie | 10BASE-T, 100BASE-T, 1000BASE-T |
Full duplex | Ja |
Data-uitwisseling | |
Switchingcapaciteit | 1024 Gbit/s |
Beveiliging | |
Access Control List (ACL) | Ja |
Ondersteunde beveiligingsalgoritmen | AES, HTTPS, SNMPv3, SSH-2 |
SSH/SSL support | Ja |
Authenticatie type | AAA |
Design | |
Rack-montage | Ja |
Vormfactor | 1U |
Kleur van het product | Grijs |
Ventilatiesysteem | Luchtstroom achter-naar-voor |
Aantal ventilatoren | 2 ventilator(en) |
Energie | |
Stroombron | AC |
Vermogenstoevoer inclusief | Ja |
Redundante voeding | Ja |
Aantal voedingen | 1 |
AC-ingangsspanning | 100 - 240 V |
AC-ingangsfrequentie | 50 - 60 Hz |
Vermogensverbruik (max) | 650 W |
Power over Ethernet (PoE) | |
Power over Ethernet (PoE) | Nee |
Eisen aan de omgeving | |
Bedrijfstemperatuur (T-T) | 0 - 45 øC |
Temperatuur bij opslag | -40 - 70 øC |
Relatieve vochtigheid in bedrijf (V-V) | 10 - 90 procent |
Luchtvochtigheid bij opslag | 10 - 95 procent |
Hoogte, in bedrijf | -60 - 2000 m |
Gewicht en omvang | |
Breedte | 510,8 mm |
Diepte | 439,4 mm |
Hoogte | 43,7 mm |
Gewicht | 9,1 kg |
Warranty | |
Base Warranty | Non Non |