NetShelter Rack PDU Advanced Metered 34.6kW 3PH 415V 60A 560P6 42 Outlet
ITCurry #: 0280K957 | Article #: APDU10450ME-
ScreenMemoryWeightProcessorHard DiskSSDScreenResolutionConnectivityMemoryCaseOSScreenTypeSpeed BlackSpeed ColourModelProcessor SpeedForm FactorInternal / ExternalPort CountUplink / mediaMounting
- View All Specs
Bundles
Related products
Product Information
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2 wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.
Design | |
PDU types | Switched |
Type | Single-phase |
Rack capacity | 0U |
Mounting | Vertical |
Product colour | Black |
Display | LCD |
On/off switch | No |
Ports & interfaces | |
AC outlets quantity | 48 AC outlet(s) |
Power plug | IEC 60309 |
AC outlet types | C13 coupler, C15 coupler, C19 coupler, C21 coupler |
Features | |
Daisy chain | Yes |
Certification | CSA C22.2 No 62368-1, FCC part 15 subpart B, UL 62368-1 |
Power | |
Nominal input voltage | 415 V |
AC input frequency | 50 - 60 Hz |
Maximum current | 60 A |
Nominal output voltage | 240 V |
Output voltage | 240 V |
Load capacity | 34600 VA |
Maximum input current per phase | 60 A |
Maximum total current draw per phase | 48 A |
Weight & dimensions | |
Width | 56 mm |
Depth | 75 mm |
Height | 1826 mm |
Weight | 11.7 kg |
Packaging data | |
Package weight | 14.7 kg |
Package width | 262 mm |
Package depth | 132 mm |
Package height | 1980 mm |
Operational conditions | |
Operating temperature (T-T) | -5 - 60 øC |
Storage temperature (T-T) | -25 - 65 øC |
Operating relative humidity (H-H) | 5 - 95% |
Storage relative humidity (H-H) | 5 - 95% |
Operating altitude | 0 - 3048 m |
Non-operating altitude | 0 - 15240 m |
Warranty | |
Base Warranty | Non Non |